Skip to content
All Our Prices Are Inclusive of Vat.
All Our Prices Are Inclusive of Vat.

C-TEC 2, 4 & 8 Zone Build Your Own Custom Fire Alarm Kit

SKU
Original price £0.99 - Original price £164.99
Original price
£119.99
£0.99 - £164.99
Current price £119.99

C-TEC  2, 4 & 8 Zone economy fire alarm panels

Part no: CFP702E-4, CFP704E-4 & CFP708E-4

  • LPCB certified to EN54-2/4, C-TEC's CFP economy fire alarm panels offer an array of user and installer-friendly features.
  • Supplied in an attractive flush or surface mountable plastic enclosure, they include detector zones, four conventional sounder circuits, class change and alert inputs, four open collector outputs (fire, fault, reset and remote) and combined keypad/keyswitch entry.
  • Unlike the Standard CFP fire alarm panels, the economy panels are NOT compatible with CFP repeaters, relay expansion boards or EN54-13 interface cards. It also has limited engineering functions.

2x Security Intruder Alarm Battery 12V 2.1Ah

Part no: CA1221

  • Mainly Used in intruder alarm control panels and Fire Alarm Panels to power the alarm in the event of a power failure
  • Dimensions: 179mm wide x 64mm high (including terminals) x 35mm deep

C-TEC Activ Optical Smoke Detector C4416 for Fire Alarm Panel

Part no: C4416

  • A high-quality optical smoke detector offering outstanding detection performance at a very competitive price.
  • Manufactured by C-TEC in the UK.
  • Third-party certified to EN54-7 by Intertek.
  • Wide 6-33V DC operating voltage.
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
  • Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels.
  • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

C-TEC ActiV Rate of Rise Heat Detector C4403A1R for Fire Alarm Panel

Part no: C4403A1R

  • A high-quality Type A1R static/rate of rise heat detector offering outstanding detection performance at a very competitive price.
  • Manufactured by C-TEC in the UK.
  • Third-party certified to EN54-5 by Intertek.
  • Wide 6-33V DC operating voltage.
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
  • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

C-TEC ActiV Diode Base C4408/C4408D Diode for Fire Alarm Panel

Part no: C4408/C4408D

  • Compatible with C-TEC’s entire range of ActiV fire detectors.
  • Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors.
  • Easy to fit with lots of working space.
  • Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors.
  • Integrated detector/base locking mechanism, head removal tool and ID tag.
  • Simple ‘click and twist’ design.
  • Remote LED terminals for the optional connection to a BF318 Remote indicator.
  • C4408 non-diode and C4408R relay bases also available.

KAC Conventional Manual Call Point, Break Glass

Part No: BF370R or MCP1A-R470SG-STCK-01

  • This KAC Call Point MUS1A-R470FG-01 is specifically designed to be used on Conventional / Non-Addressable Fire Alarm Systems.  It has an internal 470 Ohm resistor and comes in Red.
  • This unit is designed to be flush mounted. This KAC Call Point comes complete with a frangible glass element and manual test key which enables the user to carry out a manual test without breaking the glass.
  • Conventional Manual Call Point
  • Complete with Surface Back box
  • Complete with Test Key
  • Supplied with Frangible Glass Element
  • Integral 470 Ohm Resistor

KAC Conventional Resettable Manual Call Point No Break Glass
Part No. BF370MR

  • The BF370MR and BF370MFR are ‘no break’ resettable versions of the crack glass call points described above. Instead of a ‘crack glass’ element, they feature a plastic resettable element, making them ideal for use in applications where there are high levels of nuisance calls/vandalism.
  • Unique ‘Plug & Play’ installation concept
  • Total ‘Flex-Ability’ in the choice of operating element
  • Anti-Tamper facility
  • Enhanced aesthetics
  • Fully approved to the latest standards
  • Backward compatibility
  • Integral 470 Ohm Resistor

C-Tec BF431C/CC/W ActiV 96dB(A) Conventional Base Sounder

Order code: BF431C/CC/W

  • Third-party certified to EN54-3 (Sounders).
  • Impressive 96dB(A) sound output @ 1m.
  • Includes 31 selectable primary tones and an optional secondary tone.
  • Two volume levels (high and low)
  • Alarm Current at 30Vdc = 5.5mA
  • Alarm Current at 18Vdc = 3.8mA
  • Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
  • Supplied with a BF431QCP quick connect plate and detector spur wires.
  • IP21C rated.
  • 122mm diameter x 46mm deep (not including optional detector and base).

Eaton 540503FULL-0403X Sounder Deep Base Red

Part no: 540503FULL-0403X or ROLP/SV/R/D/3

  • The Eaton-Fulleon surface mount Roshni Low Profile (RoLP) is renowned as the fire alarm markets leading conventional sounder, but can be used in numerous other applications, such as security, general signalling and automation process & control alarms. Roshni process sounders can operate from either a low voltage AC or a DC supply and the wide range of tones enable the sounder to be used for many different uses. This capable sounder is suitable for use in a wide range of applications in a myriad of industries.
  • Ideal for general signalling and for fire alarm siren use, this sounder is fire approved and has 32 general signalling tone alert options and alarm functions to reduce confusion. This sounder has been created and designed for reliability whilst in operation offering very high specs, rugged low-profile casing and encapsulated electronics.

Eaton 8210113FULL-0016X Beacon Sounder Deep Base Red

Part no: 8210113FULL-0016X or ROLPSB/RL/R/D

  • Eaton-Fulleon sounder beacon complete with a Roshni Solista low profile deep base. These sounder beacons are utilised to supplement audible alarms within an industrial alarm/notification installation and are becoming increasingly common. This capable combined sounder beacon, with 32 user selectable tones, allows for both an audible and visual alarm, but it requires only a single installation point. The highly visible LED beacon has a dramatically lower current consumption than that of traditional Xenon beacons, making it ideal for applications where sounder circuit capacity is limited.

C-Tec BF431C/CC/W ActiV 96dB(A) Conventional Base Sounder

Order code: BF431C/CC/W

  • Third-party certified to EN54-3 (Sounders).
  • Impressive 96dB(A) sound output @ 1m.
  • Includes 31 selectable primary tones and an optional secondary tone.
  • Two volume levels (high and low)
  • Alarm Current at 30Vdc = 5.5mA
  • Alarm Current at 18Vdc = 3.8mA
  • Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
  • Supplied with a BF431QCP quick connect plate and detector spur wires.
  • IP21C rated.
  • 122mm diameter x 46mm deep (not including optional detector and base).

C-TEC BF319 Fire Alarm Control Panel Mains Keyswitch Double Pole

Part no: BF319

  • A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
  • Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
  • Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
  • Fits on a standard UK 47mm flush or surface mount back box.
  • Supplied with 2 x M3.5 25mm fixing screws.
  • BS EN60669-1 compliant.

1.5mm 2 Core & Earth Fire Alarm Cable 100m

  • FP200 Equivalent
  • Red

1.5mm 2 Core & Earth Fire Alarm Cable Per m

  • FP200 Equivalent
  • Please purchase the amount you require and we will cut the cable to the length
  • Red

Robson Products P Clips 50 Pack LSFC7R

Part No: LSFC7R

  • 7mm to suit 1.5mm 2 core & Earth fire alarm cable
  • Red

Unicrimp 7-10mm PVC Round Cable Clips Red 100 Pack QRC9

Part No: QRC9

  • 7mm-10mm to suit 1.5mm 2 core & Earth fire alarm cable
  • Red
  • Plastic

C-tec CFP Panel Spare / Replacement End of Line Unit – Detector Circuit

Part No: CFP-EOL

  • Spare / Replacement Detection Circuit End Of Line Unit
  • This device is a replacement End of Line unit for use with the C-Tec CFP Conventional Fire Alarm Panel range.
  • This product is designed to be used on the detection zone circuits.
  • This product has the following details marked on the outside of the component: -
  • EOL
  • RCN1050368

KAC Spare Glass for Manual Call Point

Part No: BF371 KG1

  • Spare Glass for manual call point

C-TEC Fire Alarm Panel Spare Test Key

Part No: S-KEY

  • Spare / Replacement CFP Fire Alarm Panel Key
  • Allows access to the user control buttons

KAC Manual Call Point Spare Test Key

Part No: BF370KRK or SC070

  • Compatible with the KAC old & new range of call points
  • Allows the user to perform a manual test without breaking the glass

KAC Manual Call Point Plastic Protective Cover

Part No: BF370MC or PS200

  • Call Point Cover
  • Helps Prevent Accidental Alarm Activations
  • Made From Tough Polycarbonate Plastic

Apollo Test Key for Manual Call Point

Part No: 44251-176

  • The Apollo 44251-176 are test keys for use with the new type Apollo call points.  They allow the user to perform a manual test on the call point to test for correct operation.
  • The Apollo 44251-176 Call Point Test Keys are for use with the following devices:-
  • Apollo SA5900-908 XP95 / Discovery Call Point
  • Apollo 55200-905 XP95 Addressable Call Point
  • Apollo 55200-908 XP95 Addressable Call Point with Isolator
  • Apollo 58200-950 Weatherproof Manual Call Point
  • Apollo 58200-951 Weatherproof Manual Call Point with Isolator
  • Apollo 58200-910 Discovery Manual Call Point
  • Apollo 58200-908 Discovery Manual Call Point with Isolator
  • Apollo 58200-926 Discovery Indoor White Call Point
  • Apollo 58200-927 Discovery Indoor Yellow Call Point
  • Apollo 58200-928 Discovery Indoor Blue Call Point
  • Apollo 58200-929 Discovery Indoor Green Call Point
  • Apollo 58200-930 Discovery Indoor Orange Call Point

Fike Rafiki Test Key Manual Call Point

Part No: 45-0022-S - Fike

  • The 45-0022-S is the new cut test key which is suitable for the Fike Twin flex and Sita range of Call Points.

White Burglar Alarm Surface Door Contact Magnetic 5 Terminal Contact Type

  • Professional quality white surface contacts, designed to be fitted to doors or windows. These measure approx 67mm x 12mm x 13mm and have an operating gap of up to 20mm. As you can see in the picture they come with fitting screws. There are five terminals on the back of these contacts, the silver terminals for the alarm circuit and the brass terminals for connecting tamper circuits etc.
  • Grade 1, Environmental Class 2 contacts with an operating gap of around 20mm, Colour white, fixing screws included. These are normally closed contacts (when door is closed circuit is closed) and therefore work with all the leading brands of burglar alarm panels: ADE, Honeywell, Accenta, Optima, Gardtec, Risco etc.

Aico Ei1529RC Mains Powered Hard Wired Alarm Remote Control Switch 230V

  • Install as part of the system to get more control over your alarms
  • Mains powered
  • Hard wired interconnection
  • Test, Locate and Silence
  • Compatible with 3000, Ei2110e Multi-Sensor Fire Alarm, 160e Series alarms, 140e Series alarms and hard-wired interconnected Carbon Monoxide alarms